This product is well-suited for small IT environments due to its affordability and switched power control capabilities. Users appreciate its compact design and automatic transfer switching feature. However, some users find it limited in terms of input voltage range and power capacity.
REASONS TO BUY
Switched Power Control - Allows for individual outlet control and remote monitoring
Automatic Transfer Switching - Ensures continuous operation by switching between two power sources
Compact Design - Fits neatly into a 1U rack space
Affordable - Suitable for smaller budgets
CONSIDERATIONS
Limited Input Voltage Range - Only supports 120V, which may not be suitable for all setups
Limited Power Capacity - May not be sufficient for high-power devices
About AI Content: Vantage Point by Provantage utilizes AI-generated content to enhance your experience, provide product recommendations, and deliver helpful information. While we strive for accuracy and quality, AI-generated content may occasionally contain errors or outdated information. Please verify details before making purchasing decisions.
Tripp Lite Series PDU Switched ATS 120V 15A 5-15R 8 Outlet 2 5-15P Horizontal 1U
Summary
Rear View
Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 millisecond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Installed web/network monitoring card enables remote power monitoring and control. Remotely displays status of input power, load capacity, and outlet power condition via secure network or web browser interface. Offers individual outlet control to power on, off, or cycle AC output to regain control of locked-up servers and other network devices. Load ramping and shedding provides automatic power management to any type of network configuration. Supports notification and logging of input power status, event notification, output power and PDU loading conditions. Supports 1U rackmount installation in a 2 or 4 post racks. Included are 8 NEMA 5-15R outlets and two 12 ft. 5-15P optional-use dual cords for auto-transfer switching (ATS) option.
Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS systems or to create a redundant dual-UPS power source for a critical, single-corded network device. Front AC input LED's show what input AC source is being utilized by the PDU.
Details
Front View
Features Include
120V 15A metered PDU system with Automatic Transfer Switch (ATS)
Dual input cords, one attached (primary) and one optional-use detachable cord (secondary)
Included cordsets support 5-15P plug-in connection
Front panel digital ammeter displays power consumption in amps.
Web/Network monitoring card enables remote power monitoring and control of power to each outlet
8 built-in NEMA 5-15R output receptacles
Optional ATS function enables setup for hot-swappable UPS maintenance bypass, dual UPS protection or dual AC input redundancy for critical single-corded network hardware
Small 1U rackmount format installs in only one rack space with a maximum installed depth of 14.5 inches
Also supports 0U vertical mounting in the cable managment area of many rack enclosures
Indvidually controlled outlets provide load management to networked equipment
Sequential outlet turn on eliminates power up in-rush of connected devices on initial power up
In the box
PDU with attached 5-15P input power cord
Detachable C13 to NEMA 5-15P 12 ft / 3.6m power cord for optional secondary input
Single phase 15A 120V Auto Transfer Switch / ATS PDU
Built-in Java-free LX Platform interface for 24/7 remote access
Enables redundant A/B power option for single-corded network devices
Separate primary & secondary inputs connect to any two compatible power sources
1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
Individually switched outlets; Two digit visual current meter
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Overview
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:
Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.
Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.
Information is current to the best of our knowledge. However, prices, promotions, specifications, photos, or offers may change before we are able to update our website. If there's an unexpected cost increase, we will ask you whether you want to continue your order at the new price or cancel it. We reserve the right to decline acceptance of any order.