HomeIndexesTripp LitePDUMH20ATNET

 

Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal

Tripp Lite PDUMH20ATNET

Click image to enlarge or see more views.

Volume Discounts
Contact us and save even more if you meet these Big Deal qualifications.
Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Model PDUMH20ATNET

UPC Code: 037332136411

Provantage Code:  TRPL1LA

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L5-20P
  • PDU Type: Switched
  • Receptacle Detail: 16 x NEMA 5-15/20R
  • Country of Origin: Taiwan
  • TAA Compliant: Yes

TAA CompliantBig DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Tripp Lite PDUMH20ATNET Specifications

    Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal


Summary


    Rear View
    Tripp Lite's 120V 20A metered PDU system with Automatic Transfer Switching (ATS) is a 16 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned-on at 250 millisecond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Installed web/network monitoring card enables remote power monitoring and control. Remotely displays status of input power, load capacity, and outlet power status via secure network or web browswer interface. Offers individual outlet control to power on, off, or cycle AC output to regain control of locked-up servers and other network devices. Load ramping and shedding provides automatic power management. Supports notification and logging of input power status, event notification, output power and load conditions. Supports 1U rackmount installation in a 2 or 4 post racks. Included are 16 NEMA 5-15/20R outlets, and optional-use dual cords for auto- transfer switching (ATS) options. Each input plug supports 5-20P and L5-20P input.

    Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS systems or to create a redundant dual-UPS power source for a critical, single-corded network device. Front AC input LED's show what input AC source is being utilized by the PDU.

Details

    Features Include
    • 120V 20A metered PDU system with Automatic Transfer Switch (ATS)
    • Dual input input cords, one attached (primary) and one optional-use detachable cord (secondary)
    • Included cordsets support 5-20P and L5-20P plug-in connections via secure adapters
    • Front panel digital ammeter displays power consumption in amps
    • Web/Network monitoring card enables remote power monitoring and control of power to each outlet
    • 16 built-in NEMA 5-15/20R output receptacles
    • Optional ATS function enables setup for hot-swappable UPS maintenance bypass, dual UPS protection or dual AC input redundancy for critical single-corded network hardware
    • Small 1U rackmount format installs in only one rack space with a maximum installed depth of 14.5 inches
    • Also supports 0U vertical mounting in the cable managment area of many rack enclosures
    • Individually controlled outlets provide load management to networked equipment
    • Sequential outlet turn on eliminates power up in-rush of connected devices on initial start-up

At a Glance

    • 1.9kW 120V ATS / Switched PDU, Single phase 20A 120V
    • Enables redundant A/B power option for single-corded network devices
    • Separate primary & secondary inputs connect to any two compatible power sources
    • 1U horizontal rackmount; 2 L5-20P / 5-20P inputs; 16 5-15/20R outlets
    • Individually switched outlets and Built-in LX Platform; Two digit visual current meter
    • Temperature, humidity and contact closure monitoring options
    • TAA Compliant

Overview

    Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

    More from the Manufacturer

Management

    • Integrated Automatic Transfer Switch (ATS) allows PDU to operate from secondary input source when primary input fails
    • Sequential outlet power-on prevents inrush-related equipment interaction on startup
    • Programmable or real-time monitoring and outlet power control via secure web/network interface

Certifications & Standards

Package Contents

    • PDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
    • PDU with attached L5-20P input power cord
    • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
    • Two NEMA L5-20R to NEMA 5-20P plug adapters
    • User manual with warranty information


Specifications

Product NameTripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal
Product TypePDU
Receptacle TypeNEMA 5-15/20R
TAA CompliantYes
PDU TypeSwitched
Power Rating (VA)2400 VA
Product ColorBlack
Receptacle Detail16 x NEMA 5-15/20R
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Rack Height1U
Plug / Connector TypeNEMA L5-20P
Mount TypeRack-mountable
Input Voltage120 V AC
Output Voltage120 V AC
Environmentally FriendlyYes
Plug / Connector Detail2 x NEMA L5-20P
Country of OriginTaiwan
Height1.8"
Width1.8"
Depth14.5"
Product ModelPDUMH20ATNET
Limited Warranty2 Year
Number of Cord / Cable2
Color FamilyBlack
 
Supplies/Accessories for Tripp Lite PDUMH20ATNET



Tripp Lite SMART ONLINE UPS 2200VA 120V RM 1800W 2U LCD USB DB9 7 OUT

Mfg Part# SU2200RTXLCDN


Tripp Lite 1U Rack-Mount Console with 19-in. LCD

Mfg Part# B021-000-19



The Following Are Compatible With Tripp Lite PDUMH20ATNET



Tripp Lite SMART ONLINE UPS 2200VA 120V RM 1800W 2U LCD USB DB9 7 OUT

Mfg Part# SU2200RTXLCDN




Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:

Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Shop with confidence! Provantage is an authorized Tripp Lite dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

Tripp Lite
 
© Copyright 1984-2024 Provantage
Tripp Lite Model PDUMH20ATNET