Contact us and save even more if you meet these Big Deal qualifications.Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.
Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.
Tripp Lite's 200-240V 16A Switched, Metered PDU system with Automatic Transfer Switching (ATS) offers 8 switched C13 outlets and 2 unswitched C19 outlets, plus a digital display to indicate total connected equipment power consumption level in amps. Switched outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup. Built-in web/network monitoring card enables remote power monitoring and programmable or real-time outlet control. Remote interface displays status of input power, load capacity and outlet power status via secure network or web browser interface. Offers individual outlet control to power on, off, or cycle AC output to regain control of locked-up servers and other network devices. Programmable load ramping and shedding enables user-configurable startup and shutdown sequences, including UPS load management to automatically increase runtime for the most critical connected items by shutting down less critical items at user-determined intervals. Supports notification and logging of input power status, event notification, output power and output loading conditions. Supports 1U rackmount installation in a 2 or 4 post racks.
Details
Features Include
200-240V 16A Switched, Metered PDU system with Automatic Transfer Switch (ATS) option
Two C20 inlets support connection to Primary and optional Secondary power sources
Built-in C20 inlets support a variety of user-supplied cordsets
Front panel digital ammeter displays power consumption in amps
Web/Network monitoring card enables remote power monitoring and control of power to each switchable C13 outlet
8 built-in C13 switched outlets and 2 unswitched C19 outlets
ATS function enables setup for hot-swappable UPS maintenance bypass, dual UPS protection or dual AC input redundancy for critical single-corded network hardware (ATS function requires the use of a full time sine wave online UPS on the Primary input, like Tripp Lite's SmartOnline series)
ATS functionality with 2-5 millisecond transfer time is supported by any two 200-240V AC power sources, regardless of phase angle, to offer support for a variety of unique redundant power applications
Small 1U rackmount format installs in only one rack space with a maximum installed depth of 14.8 inches
Also supports 0U vertical mounting in the cable managment area of many rack enclosures
Individually controlled outlets provide load management power control to networked equipment
Sequential outlet turn on eliminates power up in-rush of connected devices on initial start-up
In the box
Switch, Metered PDU with ATS Support
User manual with warranty information
At a Glance
Single phase 16/20A 200-240V Auto Transfer Switch / ATS PDU
Enables redundant A/B power option for non-redundant network devices
Individually switched outlets, network interface and 2 digit visual current meter
TAA Compliant
Overview
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:
Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.
Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.