HomeIndexesServer TechnologyC2XG24SN-DCLN5D6

 

Server Technology Switched PRO2 Expansion Pops Pips, 2U, (18) IEC C13 and (6) CX Hdot Outlets, Input

Server Technology C2XG24SN-DCLN5D6
Volume Discounts
Contact us and save even more if you meet these Big Deal qualifications.
PDU's Qualify for discounts, ask a sales rep for special pricing today!

Series PRO2

Manufacturer Part#  C2XG24SN-DCLN5D6

Provantage Code:  SETE2XC

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L15-30P
  • Input Current: 30 A
  • Product Family: PRO2
  • PDU Type: Switched

Big DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Server Technology C2XG24SN-DCLN5D6 Specifications

    Switched PRO2 Expansion Pops Pips, 2U, (18) IEC C13 And (6) CX Hdot Outlets, Input Amp Meters, 208V 3-Phase 30A, NEMA L15-30P, 10 Ft (3.04 M) Input Cord, (2) Temperature/ Humidity Sensor Capable, Breaker Branch Circuit Protection


At a Glance

    • HDOT Cx: Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
    • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
    • Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
    • Temperature/Humidity Monitoring: Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
    • Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
    • Per-Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
    • Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
    • Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
    • Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
    • Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
    • High Retention Locking Outlets: PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
    • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Overview

    The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Application/Usage

    IT Equipment

    Server Rack/Cabinet

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • v3 (GET, SET, Traps)
    • IPv4 and IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP

Certifications & Standards

    Safety (Listed & Certified, cTUVus mark):

    • UL 62368-1
    • CSA C22.2 No. 62368-1

    EMC:

    • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
    • CANICES-003, Class A


Specifications

Product NameSwitched PRO2 Expansion Pops Pips, 2U, (18) IEC C13 and (6) CX Hdot Outlets, Input
Manufacturer Part NumberC2XG24SN-DCLN5D6
Product TypePDU
PhaseThree Phase
Receptacle TypeIEC 60320 C13

CX

Product FamilyPRO2
PDU TypeSwitched
Remote Outlet SwitchingYes
Power Rating (Watt)8600 W
Locking ReceptaclesP-Lock
Receptacle Detail18 x IEC 60320 C13

6 x CX

Plug / Connector TypeNEMA L15-30P
FeaturesLED Display
Input Current30 A
Mount TypeRack-mountable

Cabinet-mountable

Button Mount

Protection TypeBranch Circuit

Circuit Protection

Fuse

Input Voltage230 V AC
Output Voltage208 V AC
Input Frequency60 Hz
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature122°F (50°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Network (RJ-45)Yes
Load Capacity (Watt)8600 W
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Height3.5"
Width17.2"
Depth17.5"
Product SeriesPRO2
Limited Warranty2 Year
Circuit BreakerYes
Supplies/Accessories for Server Technology C2XG24SN-DCLN5D6




Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Server Technology BIG DEAL qualifications:

PDU's Qualify for discounts, ask a sales rep for special pricing today!


Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology Series PRO2 C2XG24SN-DCLN5D6