Manufacturer Part#  C3W36RL-2CJE2MT4

Provantage Code:  SETE2W8

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L6-30P
  • Input Current: 30 A
  • Product Family: PRO3X
  • PDU Type: Switched

Big DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Server Technology C3W36RL-2CJE2MT4 Specifications

    Switched PRO3X with Pips, 0U, 36 Ramlock Hdot Outlets (18 C13 + 18 CX), Color Matrix LCD, 208V/1-Phase (L-L)/30A, Input: NEMA L6-30P, 3M (10FT) Cord (End Of the PDU, Outlet 1 on End Opposite Power Cord)Support for Raritan DX2 Sensors


At a Glance

    • HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
    • Network Monitoring: Gain access to valuable data through connections including: HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
    • Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
    • Hot Swappable Controller: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
    • RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
    • Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
    • Per-Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
    • Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
    • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
    • Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
    • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
    • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
    • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Overview

    This all new Server Technology PRO3X Switched PDU features RamLock HDOT outlets running with the Xerus Technology Platform's state of the art network interface module. Server Technology's unique RamLock, a self-locking, elbow-catch mechanismto prevent accidental cord disconnects on standard power cords. The PDU features HDOT outlets which are dedicated C13 outlets, while the other HDOT Cx outlets can be treated as either a C13 or C19 outlet. This innovative PDU combines input power and branch current monitoring, and outlet control and supports Legrand plug-and-play sensor types like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • v3 (GET, SET, Traps)
    • IPv4
    • IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP

Certifications & Standards

    Safety (Listed & Certified, cTUVus mark):

    • UL 62368-1
    • CSA C22.2 No. 62368-1

    EMC:

    • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
    • CANICES-003, Class A

Package Contents

    • PRO3X 36-Outlets PDU
    • Standard Button Mounts


Specifications

Product NameSwitched PRO3X with Pips, 0U, 36 Ramlock Hdot Outlets (18 C13 + 18 CX), Color
Manufacturer Part NumberC3W36RL-2CJE2MT4
Product TypePDU
PhaseSingle Phase
Receptacle TypeIEC 60320 C13

CX

Product FamilyPRO3X
PDU TypeSwitched
Remote Outlet SwitchingYes
Power Rating (Watt)5000 W
Locking ReceptaclesRamLock Locking Outlet
Receptacle Detail18 x IEC 60320 C13

18 x CX

Rack Height0U
Plug / Connector TypeNEMA L6-30P
FeaturesMulti-color LCD
Input Current30 A
Mount TypeButton Mount
Protection TypeBranch Circuit

Circuit Protection

Fuse

Input Voltage230 V AC
Output Voltage208 V AC
Input Frequency60 Hz
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Network (RJ-45)Yes
Load Capacity (Watt)5000 W
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Height70"
Width2.2"
Depth2.5"
Product LinePRO3X
Application / UsageData Center
Limited Warranty2 Year
Circuit BreakerYes
WARNING: Products made with PVC can expose you to chemicals including DEHP, which is known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Supplies/Accessories for Server Technology C3W36RL-2CJE2MT4


Raritan Asset Management Sensor Bar 48-Port

Mfg Part# AMS2-48


Raritan DX2-T1 Temperature Sensor RJ 45

Mfg Part# DX2-T1


Raritan DX2 T2H2 2 Temperature 2 Humidity Sensors

Mfg Part# DX2-T2H2



Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Server Technology BIG DEAL qualifications:

PDU's Qualify for discounts, ask a sales rep for special pricing today!


Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology PRO3X C3W36RL-2CJE2MT4