Server Technology C2LG36TE-2CAF2M66 Specifications
Smart Pops Exp 36 Config 208V 30A L6-30P
At a Glance
HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot-Swap Network Card: Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
Star Multi-Linking: PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
Temperature/Humidity Monitoring: Primary and Expansion (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
Per Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Per Outlet Power Sensing: POPS® (Per Outlet Power Sensing) monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
Overview
The Server Technology® PRO2 Smart POPS PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart POPS "Primary"PDU can be connected to as many as three (with optional module) PRO2 Smart POPS "Link"PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Application/Usage
IT Equipment
Server Rack/Cabinet
Management
HTTP/HTTPS
TLSv1.2
SSHv2
Telnet
SNMPv2c
v3 (GET, SET, Traps)
IPv4
IPv6
LDAPv3/LDAPS
TACACS+
RADIUS
FTP/SFTP
Certifications & Standards
Safety (Listed & Certified, cTUVus mark):
UL 62368-1
CSA C22.2 No. 62368-1
EMC:
FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
WARNING: A UPS contains batteries that have battery posts, terminals and related accessories that can expose you to lead and/or lead compounds as well as other chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.