Switched (Expansion Unit) PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3M (10FT) Cord (Front Cord Entry), 20 A Circuit Breakers
At a Glance
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets.
Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
High Retention Locking Outlets: Receptacles have high retention and are compatible with PLock type power cords.
Color Identification: Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
Temperature/Humidity Monitoring: Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Per-Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy
Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
Overview
The Server Technology® PRO1 Switched Rack PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Master" PDU can be connected to as many as three PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Switched (Expansion Unit) PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets
Manufacturer Part Number
C1X16HR-2CAA5BAC
Product Type
PDU
Phase
Single Phase
Receptacle Type
IEC 60320 C13
Product Family
PRO1
PDU Type
Switched
Mounting Orientation
Horizontal
Power Rating (Watt)
5000 W
Environmental Sensors
Temperature/Humidity
Water
Receptacle Detail
16 x IEC 60320 C13
Rack Height
2U
Plug / Connector Type
NEMA L6-30P
Form Factor
Cabinet
Input Current
30 A
Mount Type
Rack-mountable
Protection Type
Overcurrent Protection
Double Pole
Input Voltage
230 V AC
Environmentally Friendly
Yes
Network (RJ-45)
Yes
Height
3.5"
Width
17.2"
Depth
7.1"
Product Series
PRO1
Limited Warranty
2 Year