Server Technology Switched Expansion PRO2 (54) Configurable Alt Phase Hdot Outlets, 208V, 3PH Delta

Server Technology C2X54CE-DQME2M00
Volume Discounts
Contact us and save even more if you meet these Big Deal qualifications.
PDU's Qualify for discounts, ask a sales rep for special pricing today!

Series PRO2

Manufacturer Part#  C2X54CE-DQME2M00

Provantage Code:  SETE1FV

Condition:  Factory New

  • Product Type: PDU
  • Limited Warranty: 2 Year
  • Product Family: PRO2
  • Input Voltage: 230 V AC
  • Receptacle Detail: 54 x IEC 60320 C13

Big DealsSatisfaction Guaranteed

ComputingAccessoriesVarious Accessories

Specifications

Server Technology C2X54CE-DQME2M00 Specifications

    Switched Expansion PRO2 (54) Configurable Alt Phase Hdot Outlets, 208V,3PH Delta 6BR 60A 60309 3P+Pe 3M/10FT Cord, Auto-Orient Mid Display,Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, Custom Color


At a Glance

    • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Hot-Swap Network Card: Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
    • Star Multi-Linking: PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
    • Temperature/Humidity Monitoring: Primary and Expansion (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
    • IP Access, Security & Communications: Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.
    • Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
    • Per-Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
    • Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
    • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
    • Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
    • Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
    • HDOT (High Density Outlet Technology): The highest outlet density available in a network-connected PDU. Meets IEC C13 and C19 specifications, plus high native retention, and UL94V-0 flame rating.
    • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
    • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
    • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Overview

    The Server Technology® PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration

Application/Usage

    IT Equipment

    Server Rack/Cabinet

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • v3 (GET, SET, Traps)
    • IPv4 and IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP

Certifications & Standards

    Safety (Listed & Certified, cTUVus mark):

    • UL 62368-1
    • CSA C22.2 No. 62368-1

    EMC:

    • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
    • CANICES-003, Class A

Package Contents

    • PRO2 54-Outlets PDU
    • Button Mounts


Specifications

Product NameSwitched Expansion PRO2 (54) Configurable Alt Phase Hdot Outlets, 208V, 3PH Delta
Manufacturer Part NumberC2X54CE-DQME2M00
Product TypePDU
PhaseThree Phase
Receptacle TypeIEC 60320 C13
Product FamilyPRO2
PDU TypeSwitched
Remote Outlet SwitchingYes
Power Rating (Watt)17.30 kW
Receptacle Detail54 x IEC 60320 C13
Cord Length10 ft
Plug / Connector TypeIEC 60309 3P+G 9Hr 60A
FeaturesLED Display
Input Current60 A
Mount TypeRack-mountable

Cabinet-mountable

Protection TypeBranch Circuit

Circuit Protection

Circuit Breaker

Fuse

Input Voltage230 V AC
Output Voltage208 V AC
Input Frequency60 Hz
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Network (RJ-45)Yes
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Height80"
Width2.2"
Depth2.5"
Product SeriesPRO2
Limited Warranty2 Year
Circuit BreakerYes
Supplies/Accessories for Server Technology C2X54CE-DQME2M00




Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Server Technology BIG DEAL qualifications:

PDU's Qualify for discounts, ask a sales rep for special pricing today!


Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology Series PRO2 C2X54CE-DQME2M00