Switched (Expansion) Pops/Pips PRO2, Per Outlet And Per Input Power Sensing, 0U, (24) IEC C13 And (6) C19, (1) LED Amp Meter In the Middle, 230V, 32A with IEC 60309 2P+Pe Blue, Pivot Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers
At a Glance
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot - Swap Network Card: Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
Star Multi - Linking: PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
Temperature/Humidity Monitoring: Primary and Expansion (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Auto - Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets.
Per - Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Per - Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
Branch Current Monitoring: Monitors current at each breaker branch and provides SNMPbased alerts and emails on high usage that risks a tripped circuit.
Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses
Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
High Retention Locking Outlets: PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
Power Pivot: The 90-degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.
Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
Overview
The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary"PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link"PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Application/Usage
IT Equipment
Server Rack/Cabinet
Management
HTTP/HTTPS
TLSv1.2
SSHv2
Telnet
SNMPv2c
v3 (GET, SET, Traps)
IPv4
IPv6
LDAPv3/LDAPS
TACACS+
RADIUS
FTP/SFTP
Certifications & Standards
Safety:
ENIEC 62368-1 (TUVR certified, T-mark)
IEC 62368-1 incl. regional, national and harmonized differences (IECEE CB scheme) EMC
Switched (Expansion) Pops/Pips PRO2, Per Outlet and Per Input Power Sensing, 0U, (24
Manufacturer Part Number
SEV-6501K
Product Type
PDU
Phase
Three Phase
Receptacle Type
IEC 60320 C13
IEC 60320 C19
Product Family
PRO2
PDU Type
Switched
Power Rating (Watt)
7300 W
Locking Receptacles
P-Lock
Receptacle Detail
24 x IEC 60320 C13
6 x IEC 60320 C19
Environmental Compliance
Restriction of Hazardous Substances (RoHS)
Rack Height
0U
Plug / Connector Type
IEC 2P+PE 6Hr 230V/32A
Features
LED Display
Input Current
32 A
Mount Type
Rack-mountable
Cabinet-mountable
Protection Type
Branch Circuit
Circuit Protection
Circuit Breaker
Fuse
Input Voltage
230 V AC
Output Voltage
230 V AC
Input Frequency
60 Hz
Minimum Operating Temperature
32°F (0°C)
Maximum Operating Temperature
140°F (60°C)
Minimum Storage Temperature
-40°F (-40°C)
Maximum Storage Temperature
185°F (85°C)
Network (RJ-45)
Yes
Load Capacity (Watt)
7300 W
Minimum Operating Humidity
8%
Maximum Operating Humidity
90%
Height
69"
Width
2.2"
Depth
2.3"
Product Series
PRO2
Limited Warranty
2 Year
Circuit Breaker
Yes
WARNING: Products made with PVC can expose you to chemicals including DEHP, which is known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.