HDOT Cx: Cx is the future-ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to the network card.
Temperature/Humidity Monitoring: Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
Per-Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
Per-Outlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. POPS includes voltage, active power, apparent power, power factor, and energy.
Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
High Retention Locking Outlets: Receptacles have high retention and are compatible with P-Lock type power cords.
Color Identification: Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
Overview
The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Application/Usage
IT Equipment
Server Rack/Cabinet
Management
HTTP/HTTPS
TLSv1.2
SSHv2
Telnet
SNMPv2c
v3 (GET, SET, Traps)
IPv4 and IPv6
LDAPv3/LDAPS
TACACS+
RADIUS
FTP/SFTP
Certifications & Standards
Safety (Listed & Certified, cTUVus mark):
UL 62368-1
CSA C22.2 No. 62368-1
EN62368-1 (TUVR certified, T-mark)
IEC 62368-1 incl. regional, national and harmonized differences (IECEE CB scheme)
EMC:
FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A