Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
45 Degree Angled Infeed:
The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
Network Monitoring:
Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Multi-Unit Linking & Cascading:
Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
Multi-Color LCD:
An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
Hot Swappable Controller:
The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
Power Quality Measurements:
Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
RGB LED Outlet Indicators:
RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
Waveform Capture:
Capture voltage and current waveforms automatically or upon demand.
RamLock Locking Outlets:
A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
Environmental Monitoring:
Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
Per-Inlet Power Sensing (PIPS®):
Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Branch Circuit Protection:
This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses.
Outlet Control:
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
Alternating-Phase Outlets:
Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
High Temperature Rating:
This product has been tested and approved for safe and reliable operation in 60°C data center environments.
Flexible Mounting:
Includes standard button mounts along with provisions for custom mounting brackets.
Color-Coded Options:
Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
Overview
Server Technology's PRO4X Switched PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.