At a Glance- HDOT CX OUTLETS: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- 45 DEGREE ANGLED INFEED: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
- NETWORK MONITORING: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- MULTI-UNIT LINKING & CASCADING: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- MULTI-COLOR LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
- HOT SWAPPABLE CONTROLLER: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
- POWER QUALITY MEASUREMENTS: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
- RGB LED OUTLET INDICATORS: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
- WAVEFORM CAPTURE: Capture voltage and current waveforms automatically or upon demand.
- ENVIRONMENTAL MONITORING: Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
- PER-INLET POWER SENSING: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- PER-OUTLET POWER SENSING: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- BRANCH CIRCUIT PROTECTION: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- OUTLET CONTROL: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
|
OverviewServer Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more. |
FeaturesMulti-color LCD LCD Display |
Management- HTTP/HTTPS
- TLSv1.2S
- SHv2
- Telnet
- SNMPv2c
- v3 (GET, SET, Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
|
Product Name | 208V/60A 2P+G 6 Hour Switched Pops PRO4X IX PDU 36 Ramlock 12 C13+24CX |
Manufacturer Part Number | C4G36RA-2QBE2FE2 |
Product Type | PDU |
Receptacle Type | IEC 60320 C13 CX |
Product Family | PRO4X |
PDU Type | Switched |
Remote Outlet Switching | Yes |
Power Rating (Watt) | 10 kW |
Environmental Sensors | Temperature Humidity Water Contact Closure Air Flow Differential Pressure |
Locking Receptacles | RamLock Locking Outlet |
Plug / Connector Type | IEC 208V/60A 2P+G 6Hr |
Input Current | 60 A |
Mount Type | Rack-mountable |
Protection Type | Branch Circuit Circuit Protection Circuit Breaker Fuse |
Input Voltage | 230 V AC |
Output Voltage | 208 V AC |
Network (RJ-45) | Yes |
Receptacle Detail | 12 x IEC 60320 C13 24 x CX |
Height | 70" |
Width | 2.2" |
Depth | 2.5" |
Product Series | PRO4X |
Limited Warranty | 2 Year |
Circuit Breaker | Yes |
|